Crash Protection
Series CSR

  • Adjustable triggering sensitivity
    By controlling the air pressure, you can optimally match the sensitivity to your application.
  • Integrated sensors
    If there is a collision, the integrated sensor gives a signal to the control system to trigger an emergency stop.
  • Manual reset
    To ensure that the machine and the reason for the emergency stop are examined, the manual reset is suitable.
  1. Robot connecting flange
    partial mounting circle in accordance with EN ISO 9409-1
  2. Drive
    single-acting pneumatic cylinder response sensitivity adjustable via operating pressure with integrated spring
  3. Force transfer
    direct and low-loss at piston surface
  4. Pressure differential switch
    indirect overload recognition
  5. Sensors
    inductive proximity switch generates a signal which can be used to recognise an overload situation generates an automatic emergency off system situation included in the delivery inductive proximity switch Ø 8 mm with cable connection M8x1
  6. Connecting flange
  7. Overload recognition and compensation
    in Z-direction up to 28 mm stroke angular defection up to 12.5° on rotation around the Z-axis 360°